상세 보기
Full-scale field test for buried glass-fiber reinforced plastic pipe with large diameter
- Lee, Young-Geun;
- Kim, Sun-Hee;
- Park, Joon-Seok;
- Kang, Jun Won;
- Yoon, Soon-Jong
WEB OF SCIENCE
17SCOPUS
25초록
In this paper, we present the result of full-scale field test for buried glass fiber reinforced thermosetting polymer plastic (GFRP) pipes with large diameter (inner diameter of 2400 mm). Installation of pipe takes 10 days to complete 16 m depth backfilling layer by layer. The vertical and horizontal ring deflections are measured for 387 days. The short-term deflection measured by the field test is compared with the result predicted by the Iowa formula and the finite-difference analysis (FDA). As a result, the value calculated by the Iowa formula tends to overestimate to a considerable extent. Vertical and horizontal ring deflections calculated by the FDA agreed with test results. In addition, the long-term ring deflection is predicted by using the procedure suggested in ASTM D 5365 in the range of 40-60 years of service life of the pipe based on the experimental results. From the study, it was found that the long-term vertical ring deflection up to 60 years is less than the 5% ring deflection limitation. (C) 2014 Elsevier Ltd. All rights reserved.
키워드
- 제목
- Full-scale field test for buried glass-fiber reinforced plastic pipe with large diameter
- 저자
- Lee, Young-Geun; Kim, Sun-Hee; Park, Joon-Seok; Kang, Jun Won; Yoon, Soon-Jong
- 발행일
- 2015-02
- 유형
- Article
- 권
- 120
- 페이지
- 167 ~ 173
- 언어
- ENG
- 출판사
- ELSEVIER SCI LTD
- 발행국가
- 영국
- 분량
- 7 페이지
- ISSN
- E 1879-1085
P 0263-8223