Full-scale field test for buried glass-fiber reinforced plastic pipe with large diameter

  • Lee, Young-Geun; 
  • Kim, Sun-Hee; 
  • Park, Joon-Seok; 
  • Kang, Jun Won; 
  • Yoon, Soon-Jong
Citations

WEB OF SCIENCE

17
Citations

SCOPUS

25

초록

In this paper, we present the result of full-scale field test for buried glass fiber reinforced thermosetting polymer plastic (GFRP) pipes with large diameter (inner diameter of 2400 mm). Installation of pipe takes 10 days to complete 16 m depth backfilling layer by layer. The vertical and horizontal ring deflections are measured for 387 days. The short-term deflection measured by the field test is compared with the result predicted by the Iowa formula and the finite-difference analysis (FDA). As a result, the value calculated by the Iowa formula tends to overestimate to a considerable extent. Vertical and horizontal ring deflections calculated by the FDA agreed with test results. In addition, the long-term ring deflection is predicted by using the procedure suggested in ASTM D 5365 in the range of 40-60 years of service life of the pipe based on the experimental results. From the study, it was found that the long-term vertical ring deflection up to 60 years is less than the 5% ring deflection limitation. (C) 2014 Elsevier Ltd. All rights reserved.

키워드

Ring deflection; Experiment; Finite-difference analysis; Short-term deflection; Long-term deflection; POLYESTER POLYMER MORTARS; WINDING ANGLE; FAILURE; BEHAVIOR; PREDICTION; PRESSURE
제목
Full-scale field test for buried glass-fiber reinforced plastic pipe with large diameter
저자
Lee, Young-Geun; Kim, Sun-Hee; Park, Joon-Seok; Kang, Jun Won; Yoon, Soon-Jong
DOI
10.1016/j.compstruct.2014.10.002
발행일
2015-02
유형
Article
저널명
Composite Structures
권
120
페이지