상세 보기
Exclusion zone comparison between in free space and nuclear power plant environment
- Youn, Sangwoon;
- Park, Jong-Eon;
- Choo, Jaeyul;
- Choo, Hosung
Citations
WEB OF SCIENCE
0초록
We analyze exclusion zones (EZs) for indoor environments in nuclear power plants and compare them with the EZ in free space. When an indoor environment is considered, the lower transmitted power is recommended since multiple reflections increases stronger scattered power. The EZ area is the widest when the transmitter is at the center of the I&C room.
키워드
Indoor exclusion zone; field strength; nuclear power plant