Phenol biosensor based on hydrogel microarrays entrapping tyrosinase and quantum dots

Citations

WEB OF SCIENCE

50
Citations

SCOPUS

53

초록

This paper describes the use of microarray-based biosensor system for the determination of phenol. Microarrays based on poly(ethylene glycol)(PEG) hydrogel were prepared by photopatterning of a solution containing PEG diacrylate (PEG-DA), photoinitiator, tyrosinase, and CdSe/ZnS quantum dots (QDs). During photo-induced crosslinking, tyrosinase and QDs were entrapped within the hydrogel microarrays, making the hydrogel microarray fluorescent and responsive to phenol. The entrapped tyrosinase could carry out enzyme-catalyzed oxidation of phenol to produce quinones, which subsequently quenched the fluorescence of QDs within hydrogel microarray. The fluorescence intensity of the hydrogel microarrays decreased linearly according to phenol concentration and the detection limit of this system was found to be 1.0 mu M. The microarray system presented in this study could be combined with a microfluidic device as an initial step to create a phenol-detecting "micro-total-analysis-system (mu-TAS)".

키워드

POLY(ETHYLENEIMMOBILIZATIONNANOPARTICLESWATER
제목
Phenol biosensor based on hydrogel microarrays entrapping tyrosinase and quantum dots
저자
Jang, EunjiSon, Kyung JinKim, BumsangKoh, Won-Gun
DOI
10.1039/c0an00353k
발행일
2010
유형
Article
저널명
Analyst
135
11
페이지
2871 ~ 2878