Practical issues and solutions on installation of viscoelastic dampers in a 46-story reinforced concrete building structure

  • Ahn, Sang-Kyung
  • Min, Kyung-Won
  • Park, Ji-Hun
  • Lee, Sang-Hyun
  • Lee, Dong-Guen
  • 외 3명
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

6

초록

The purpose of this study is to evaluate the performance of viscoelastic dampers (VEDs) practically used for enhancing the serviceability of a 46-story reinforced concrete residential building structure. Considering that a bracing system for the installation of VEDs is not appropriate for a residential building because it occupies a large interior space, a method for installing VEDs at the midspan of a horizontal beam connecting the core and exterior columns is proposed. These VEDs control the total structural response in a similar way to a general outrigger system. The results from numerical analysis indicate that VEDs are effective for reducing not only mean components but also fluctuating ones of wind-induced responses by providing additional damping as well as stiffness. Copyright (C) 2007 John Wiley & Sons, Ltd.

키워드

STEEL FRAMESEISMIC BEHAVIOROPTIMAL-DESIGN
제목
Practical issues and solutions on installation of viscoelastic dampers in a 46-story reinforced concrete building structure
저자
Ahn, Sang-KyungMin, Kyung-WonPark, Ji-HunLee, Sang-HyunLee, Dong-GuenOh, Jung-KeunKim, Ki-SooLee, Sung-Kyung
DOI
10.1002/tal.353
발행일
2008-03
유형
Article
저널명
Structural Design of Tall and Special Buildings
17
1
페이지
231 ~ 243