상세 보기
초록
This study investigated via computational analysis the application utility of series-cascaded ring resonators based on silicon-on-insulator (SOI) slot optical waveguides in integrated optical biochemical sensors. The radii of the two rings in the series-cascaded ring resonators were 59.4 µm and 77.6 µm respectively, and the coupling distance was 0.5 µm. The series-cascaded ring resonators were computationally analyzed using FIMMProp and PICWave numerical software. The free spectral range (FSR), full width at half maximum(FWHM), sensitivity, and quality-factor (Q-factor) of the series-cascaded ring resonators were 12.2 nm, 0.134 nm, 4100 nm/RIU, and 11580, respectively, and the measurement range was calculated to be slightly smaller than 3×10-3 RIU. Although the measurementrange was smaller than that of the single ring resonator, upon considering other characteristic parameters, the series-cascaded ring resonators are found to be more effective as integrated sensors than single ring resonators.
키워드
- 제목
- SOI 슬롯 광도파로 기반 캐스케이드 링 공진기 바이오·케미컬 집적광학 센서의 효용성 해석
- 제목 (타언어)
- Application Utility Analysis of Series-cascaded Ring Resonators Based on SOI Slot Optical Waveguides in Integrated Optical Biochemical Sensor
- 저자
- 장재식; 정홍식
- 발행일
- 2022-09
- 저널명
- 센서학회지
- 권
- 31
- 호
- 5
- 페이지
- 353 ~ 359