판형 열교환기 전열판의 부식 파손 분석

Corrosion Failure Analysis of Flow Plate in Plate Heat Exchanger
  • 이수열
  • 송민지
  • 최가현
  • 채호병
  • 김우철
  • ... 김희산
  • 외 1명
Citations

WEB OF SCIENCE

3
Citations

SCOPUS

4

초록

Corrosion failure analysis of the flow plate, which is one of the accessories of the plate heat exchanger in a district heating system, was performed. The flow plate is made of 316 stainless steel, and water at different temperatures in the flow plate exchanges heat in a non-contact manner. The flow plate samples in which water mixing issues occurred were collected. Corrosion-induced pits, oxides, and contaminants were observed at locations where two plates are regularly in contact. The EDS analysis of the surface oxides and contaminants revealed that they were composed of carbon, silicon, and magnesium, which came from chemical adhesives. The IC/ICP analyses showed that the concentration of chloride ions was 30 ~ 40 ppm, which was not sufficient to cause corrosion of stainless steel. In the crevice, a local decrease in dissolved oxygen occurs along with an increase in chloride ions, thus forming an acidic environment. These environments destroyed the passive film of stainless steel, resulting in pits. Moreover, contaminants formed a narrower gap between the two metal plates and inhibited the diffusion of ions, thereby accelerating crevice corrosion.

키워드

Plate heat exchangerFlow plateCrevice corrosionAdhesive
제목
판형 열교환기 전열판의 부식 파손 분석
제목 (타언어)
Corrosion Failure Analysis of Flow Plate in Plate Heat Exchanger
저자
이수열송민지최가현채호병김우철김희산김정구
DOI
10.14773/cst.2021.20.4.204
발행일
2021-08-31
유형
Article
저널명
CORROSION SCIENCE AND TECHNOLOGY
20
4
페이지
204 ~ 209