초록
In this study, the thermal performance of Battery Thermal Management System (BTMS) equipped with a Pulsating Heat Pipe (PHP) cooling plate under fast charging was quantitatively evaluated. A 1D model was developed using MATLAB & Simulink to simulate the maximum temperature and the temperature difference within the battery module during fast charging. The thermal behavior of the PHP module was compared with that of an Aluminum plate module. Furthermore, the influence of rule-based current control strategy, triggered by the maximum module temperature and the maximum temperature difference within the center cell, on both the thermal response and the charging time was also compared. The results confirm that under temperature-based current control conditions, the charging time of PHP equipped battery modules can be significantly reduced by optimizing the coolant temperature.
키워드
- 제목
- PHP를 적용한 EV BTMS 모델 개발 및 PHP가 급속 충전 시간에 미치는 영향 분석
- 제목 (타언어)
- Development of an EV BTMS Model with PHP and Study of the Effect of PHP on the Fast-Charging Time
- 저자
- 김호준; 김준우; 신정헌; 조정원; 이종구; 이건구; 박성진
- 발행일
- 2026-04
- 유형
- Y
- 저널명
- 한국자동차공학회 논문집
- 권
- 34
- 호
- 4
- 페이지
- 393 ~ 409