Investigation of Pitting Corrosion of Copper Heat-Return Pipe in District Heating

  • Lee, Keun Hyung
  • Song, Min Ji
  • Kang, Tae Uk
  • Kim, Woo Cheol
  • Kim, Heesan
  • 외 1명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

This work examined pitting corrosion failure of a copper heat-return pipe used in a district heating system. The copper pipe was corroded with a 48% reduction in thickness due to localized corrosion on the inner surface exposed to heating water of 20 similar to 40 degrees C. Fe and Si elements as corrosion products were found around pits. Cl element was also observed, which accelerated oxidation of copper inside pits. Cu2O deposits on the pit's bottom surface decreased the pH inside the pit. X-ray diffraction analysis revealed hematite, cuprite, malachite and brochantite as corrosion products. Chemical analysis demonstrated that Fe and Si elements did not exist in the copper, supply water, or heating water, indicating that Fe and Si species might have entered into the pipe from the exterior. These results indicated that pits were initiated due to ion concentration gradient near Fe and Si species. Moreover, the interior of pits had lower pH due to Cl- concentration and Cu2O reactions, which accelerated the pit's growth and led to formation of pinholes. Additionally, we confirmed that the type of pitting corrosion was a complex combination of types I and II based on the HCO3-/SO42- ratio, pH, temperature, and corrosion products.

키워드

CopperPitting corrosionFailureHeat-return pipeDistrict heatingFAILURE ANALYSISTRANSPORT PIPETUBEINHIBITION
제목
Investigation of Pitting Corrosion of Copper Heat-Return Pipe in District Heating
저자
Lee, Keun HyungSong, Min JiKang, Tae UkKim, Woo CheolKim, HeesanLee, Soo Yeol
DOI
10.14773/cst.2024.23.4.315
발행일
2024-08-30
유형
Article
저널명
CORROSION SCIENCE AND TECHNOLOGY
23
4
페이지
315 ~ 323