상세 보기
Optimal Voltage Vector Selection Method for Torque Ripple Reduction in the Direct Torque Control of Five-phase Induction Motors
- Kang, Seong-Yun;
- Shin, Hye Ung;
- Park, Sung-Min;
- Lee, Kyo-Beum
WEB OF SCIENCE
6SCOPUS
10초록
This paper presents an improved switching selection method for the direct torque control (DTC) of five-phase induction motors (Mils). The proposed method is conducted using optimal switching selection. A five-phase inverter has 32 voltage vectors which are divided into 30 nonzero voltage vectors and two zero voltage vectors. The magnitudes of the voltage vectors consist of large, medium, and small voltage vectors. In addition, these vectors are related to the torque response and torque ripple. When a large voltage vector is selected in a drive system, the torque response time decreases with an increased torque ripple. On the other hand, when a small voltage vector is selected, the torque response time and torque ripple increase. As a result, this paper proposes an optimal voltage vector selection method for improved DTC of a five-phase induction machine depending on the situation. Simulation and experimental results verify the effectiveness of the proposed control algorithm.
키워드
- 제목
- Optimal Voltage Vector Selection Method for Torque Ripple Reduction in the Direct Torque Control of Five-phase Induction Motors
- 저자
- Kang, Seong-Yun; Shin, Hye Ung; Park, Sung-Min; Lee, Kyo-Beum
- 발행일
- 2017-09
- 유형
- Article
- 권
- 17
- 호
- 5
- 페이지
- 1203 ~ 1210