지역난방 냉각수 배관의 용접부 파손 분석

Failure Analysis of Welded type 304 in Cooling Water Pipeline of District Heating System
  • 김희산
  • 정준철
  • 김우철
  • 김경민
  • 손홍균
  • 외 2명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Failure analysis on the welded type 304 pipe used for cooling water piping in the district heating primary side was conducted. Inorganic elements and bacteria in the cooling water and in corrosion products were analyzed, and the weldment was inspected by microscopy and a sensitization test. Corrosion damages were observed in the heat-affected zone, on weld defects such as incomplete fusion or excessive penetration caused by improper welding, or/and at the 6 o'clock position along the pipe axial direction. However, the level of concentration of chloride in the cooling water as low as 80 ppm has been reported to be not enough for even a sensitized type 304 steel, meaning that the additional corrosive factor was required for these corrosion damages. The factor leading to these corrosion damages was drawn to be the metabolisms of the types of bacteria, which is proved by the detection of proton, sulfur containing species, biofilms, and both bacteria and corrosion product analyses.

키워드

HAZSensitizationDistrict heatingBacteriaCooling water pipeline
제목
지역난방 냉각수 배관의 용접부 파손 분석
제목 (타언어)
Failure Analysis of Welded type 304 in Cooling Water Pipeline of District Heating System
저자
김희산정준철김우철김경민손홍균김정구이수열
DOI
10.14773/cst.2020.19.6.296
발행일
2020-12
유형
Article
저널명
CORROSION SCIENCE AND TECHNOLOGY
19
6
페이지
296 ~ 301